BIRCHWOOD CASEY LABS INC -- ANTIQUE BROWN M38 -- 8010-00N045233
=====================  Product Identification  =====================

Product ID:ANTIQUE BROWN M38
MSDS Date:07/02/1990
FSC:8010
NIIN:00N045233
=== Responsible Party ===
Company Name:BIRCHWOOD CASEY LABS INC
Address:7900 FULLER RD
City:EDEN PRAIRIE
State:MN
ZIP:55344
Country:US
Info Phone Num:612-937-7940
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:51234
=== Contractor Identification ===
Company Name:BIRCHWOOD CASEY LABS INC
Address:7900 FULLER RD
Box:City:EDEN PRAIRIE
State:MN
ZIP:55344
Country:US
Phone:612-937-7940
CAGE:51234

=============  Composition/Information on Ingredients  =============

Ingred Name:ING 16:COMPLETE, ADJUST PH TO 8.0 W/CALCIUM
    CARBONATE/CALCIUM HYDROXIDE & FILTER. LIQ CAN GO DOWN DRAIN.
RTECS #:9999999ZZ

Ingred Name:NITRIC ACID, COPPER(2+) SALT; (CUPRIC NITRATE)
CAS:3251-23-8
RTECS #:QU7400000
Fraction by Wt: 6%(W/W)
OSHA PEL:1 MG/M3 (CU)
ACGIH TLV:1 MG/M3 (CU)
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:PHOSPHORIC ACID
CAS:7664-38-2
RTECS #:TB6300000
Fraction by Wt: 4%(W/W)
OSHA PEL:1 MG/M3;3 STEL
ACGIH TLV:1 MG/M3;3 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:AMMONIUM HYDROGEN FLUORIDE
CAS:1341-49-7
RTECS #:BQ9200000
Fraction by Wt: 1%(W/W)
OSHA PEL:2.5 MG/M3 (F)
ACGIH TLV:2.5 MG/M3 (F)
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:TRIDECANOL CONDENSED WITH 6 MOLES ETHYLENE OXIDE;
    (POLYOXYETHYLENE (12) TRIDECYL ALCOHOL)
CAS:24938-91-8
RTECS #:YD4571000
Fraction by Wt: 1%(W/W)
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:WATER. % WT: >85(W/W)
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: SEE ING
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SUPP DATA:TARGET ORGANS. PRECLUDE FROM CONT W/PROD THOSE
    W/WILSON'S DISEASE/DISEASES OF SKIN, LUNGS, LIVER, (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:KIDNEYS/GI TRACT. SKIN: MAY CAUSE SKIN SENSITIZATION
    RSLTG IN IRRIT, DERM/EDEMA.
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC: RESP/OXYGEN. IF CONSCIOUS & NOT VOMIT,
    INDUCE EMESIS. SEEK MED ATTN. A DIURETIC WILL SPEED ELIM (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9: OF SELENIUM. VITAMIN B COMPLEX, VITAMIN C &
    METHIONINE SUPPLEMENT ARE RECOM. SKIN: REMOVE CONTAMD CLTHG (ING
    11)
RTECS #:9999999ZZ

Ingred Name:ING 10:TO AVOID PRLNGD CONT. WASH AFFECTED AREAS W/SOAP &
    WATER. APPLICATN OF A 10% SODIUM THIOSULFATE CREAM (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11: HAS BEEN RECOMMENDED.
RTECS #:9999999ZZ

Ingred Name:WASTE DISP METH: GENERATED FROM TREATING LIQ ARE ASSIGNED
    EPA HAZ WASTE # D010 (EP TOXICITY-SELENIUM). WASTES (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:CAN BE DISPOSED OF THRU A LICENSED WASTE DISP
    COMPANY. TO TREAT LIQ & CONVERT IT TO A SOLID WASTE, ADD 2(ING 15)
RTECS #:9999999ZZ

Ingred Name:ING 14:OZ OF DEGREASED STEEL WOOL/STEEL MACHINING
    FINES/TURNINGS PER GAL OF DILUTED PROD/8 OZ PER GAL OF CONC.(ING
    16)
RTECS #:9999999ZZ

Ingred Name:ING 15:STIR FREQ/CONTINUOUSLY FOR @ LST 2 HRS. PERIODICALLY
    ADJUST PH DOWN TO 1.5 W/NITRIC ACID. WHEN RXN IS (ING 17)
RTECS #:9999999ZZ

Ingred Name:SELENIOUS ACID
CAS:7783-00-8
RTECS #:VS7175000
Fraction by Wt: 3%(W/W)
OSHA PEL:0.2 MG/M3 (SE)
ACGIH TLV:0.2 MG/M3 (SE)
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50:(ORAL,RAT)2.9 G/KG
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: PROD IS AN IRRITANT. IT
    CAN CAUSE RED OF EYES, CONJ, IRITIS, SWELL OF LIDS, A WATERY-MUCOID
    DISCHARGE & CORNEAL OPACITY. INHAL: TOX FUMES NOT GENERATED
    NORMALLY. BRTHG MISTS CAN RSLT IN L OST SENSE OF SMELL, NOSE &
    THROAT IRRIT, GARLIC ODOR OF BRTH, HDCH, DIZZ, LASSITUDE, TREMORS,
    DFCLTY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: BRTHG. TARGET ORGANS: LIVER, KIDNEYS,
    SPLEEN, LUNGS, HEART, ADRENAL GLANDS, PANCREAS. SKIN: PROD IS NOT A
    PRIMARY IRRITANT. HOWEVER, IT CAN PRDCE RED OF SKIN & SLIGHT EDEMA
    ON PRLNGD/RPTD CO NT. ALSO, IT CAN CAUSE SKIN SENSIT IN SOME
    INDIVIDUALS. CHRONIC: EYES: NO DATA SPEC TO CHRONIC EXPOS. INHAL:
    (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES: IMMED RINSE EYES THORO W/CLEAN WATER FOR @ LST 15 MIN.
    INSTILLATION OF AQUEOUS 10% SODIUM THIOSULFATE SOLN IS ALSO RECOM.
    CONSULT A PHYS. INHAL: REMOVE FROM EXPOS. IF BRTHG DFCLT, PROVIDE
    ARTF R ESP/OXYGEN. CONSULT A PHYS. WASH FOR DELAYED PULM EDEMA.
    DIURETICS SPEED ELIM OF SELENIUM. VITAMIN B COMPLEX, VITAMIN C &
    METHIONINE SUPPLEMENTS RECOMM. INGEST: IF BRTHG DFCLT, PROVIDE ARTF
    (ING 9)

=====================  Fire Fighting Measures  =====================

Flash Point:NON-FLAMMABLE
Extinguishing Media:NON-FLAMMABLE. MEDIA SUITABLE FOR SURROUNDING FIRE
    .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NON-FLAMMABLE. NON-EXPLOSIVE EXCEPT
    W/WATER- REACTIVE SUBSTANCES.

==================  Accidental Release Measures  ==================

Spill Release Procedures:RECOVER AS MUCH FREE LIQ AS POSSIBLE AND
    COLLECT IN ACID-RESISTANT CONTAINER. USE ABSORBENT TO PICK UP
    RESIDUE. AVOID DISCHARGING THE LIQUID DIRECTLY INTO SEWER/SURF
    WATERS. CERCLA REPORTABLE QTY IS 1	LB FOR SELENIOUS ACID (APPROX
    10 GALL OF PROD).
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID CO-LOADING/STORING W/CYANIDES,
    WATER- REACTIVE SUBSTANCES/STRONG REDUCING AGENTS. STORE IN
    ACID-RESIST CONTRS. PROTECT CONTRS FROM PHYSICAL DAM.
Other Precautions:WORKERS HANDLING PRODUCT SHOULD WASH BEFORE SMOKING
    OR EATING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPRVD HIGH EFFICIENCY PARTICULATE
    FILTER RESP, SUPPLIED-AIR RESP/SCBA EACH W/FULL FACEPIECE,
    HELMET/HOOD IF MISTING IS LIKELY.
Ventilation:LOCAL EXHAUST: TO KEEP MISTS BELOW TLV. SPECIAL: EQUIP FOR
    CONTAM & COLLECTION OF MISTS IF SPRAY APPLICATN USED.
Protective Gloves:RUBBER/PLASTIC.
Eye Protection:ANSI APPRVD CHEM (WORK HYGENIC PRAC)
Other Protective Equipment:AS APPROPRIATE TO OPERATION TO GUARD AGAINST
    CONTAMINATION OF CLOTHING AND PROLONGED OR REPEATED SKIN CONTACT.
Work Hygienic Practices:WORKERS HANDLING PRODUCT SHOULD WASH BEFORE
    SMOKING OR EATING. EYE PROT: WORK GOGG W/FULL LNGTH FSHLD .
Supplemental Safety and Health
PH: 1.8(20% V/V SOLN) APPROX 1.2(UNDILUTED). HAZ DECOMP: EVAP TO DRY
    CAN PRDCE SELENIUM DIOXIDE FUMES, OXIDES OF NITROEN & PHOSPHORUS, &
    MEASURABLE LEVELS OF HYDROGEN FLUORIDE. EFTS OF OVEREXP: BESIDE S
    EFTS AS IN ACUTE, CHRONIC EXPOS MAY CAUSE WEAK, PALLOR, ANEMIA
    ENLARGEMENT OF LIVER & DEGENRATIVE CHANGES IN (ING 7)

==================  Physical/Chemical Properties  ==================

HCC:C1
Boiling Pt:B.P. Text:214F,101C
Vapor Density:<1
Spec Gravity:1.055(H2O=1)
pH:SUPDAT
Evaporation Rate & Reference:>1(ETHYL ETHER=1)
Solubility in Water:COMPLETELY MISCIBLE
Appearance and Odor:ODORLESS BLUE LIQUID
Percent Volatiles by Volume:NONE

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
CYANIDES, WATER-REACTIVE SUBSTANCES, ORG SOLV, OILS, STRONG REDUCING
    AGENTS.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:RXN W/ORG & STRONG REDUCING AGENTS CAN
    PRDCE VOLAT ORGANOSELENIDES/HYDROGEN SELENIDE. THERMAL DECOMP AFTER
    (SUPP DATA)

====================  Disposal Considerations  ====================

Waste Disposal Methods:REVIEW CURRENT LOC, ST & FED; STATUTES, CODES,
    LAWS & REGS TO DETERM CURRENT STATUS & APPROP DISP METH. WASTE
    ANTIQUE BROWN M38/ITS SOLN ARE ASSIGNED EPA HAZ WASTE # D010 (EP
    TOXICITY-SELENIUM) . PREC IPITATES FILTERED FROM OPERATING BATH/
    (ING 13)

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.