SIGMA CHEMICAL CO -- MAGNESIUM CHLORIDE HEXAHYDRATE, M0250 -- 6810-00N065865
=====================  Product Identification  =====================

Product ID:MAGNESIUM CHLORIDE HEXAHYDRATE, M0250
MSDS Date:12/27/1988
FSC:6810
NIIN:00N065865
=== Responsible Party ===
Company Name:SIGMA CHEMICAL CO
Box:14508
City:ST LOUIS
State:MO
ZIP:63178
Country:US
Info Phone Num:800-325-3010
Emergency Phone Num:314-771-5765
CAGE:0DK69
=== Contractor Identification ===
Company Name:SIGMA CHEMICAL CO SIGMA DIAGNOSTICS DIV
Address:3050 SPRUCE ST
Box:City:ST LOUIS
State:MO
ZIP:63103-2530
Country:US
Phone:314-771-5765
CAGE:0DK69

=============  Composition/Information on Ingredients  =============

Ingred Name:MAGNESIUM CHLORIDE, HEXAHYDRATE
CAS:7791-18-6
RTECS #:OM2975000
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50 (ORAL RAT): 8100 MG/KG.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MAY BE HARMFUL BY INHALATION,
    INGESTION OR SKIN ABSORPTION. CAUSES EYE & SKIN IRRITATION.
    IRRITATING TO MUCOUS MEMBRANES & UPPER RESP TRACT. EXPOS CAN CAUSE
    STOM PAINS, VOMIT, DIARR. TARGET ORG AN DATA: BEHAVIORAL
    (SOMNOLENCE, EXCITEMENT). CHRONIC: TO BEST OF MFR KNOWLEDGE, CHEM,
    PHYSICAL, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: & TOXICOLOGICAL PROPERTIES HAVE NOT
    BEEN THOROUGHLY INVESTIGATED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYES: IMMEDIATELY FLUSH WITH COPIOUS AMOUNTS OF WATER FOR AT
    LEAST 15 MINUTES. SKIN: IMMEDIATELY WASH WITH SOAP AND COPIOUS
    AMOUNTS OF WATER. INHALATION: REMOVE TO FRESH AIR. IF NOT
    BREATHING, GIVE AR TIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT,
    GIVE OXYGEN. CALL MD. INGESTION: CALL MD IMMEDIATELY . WASH
    CONTAMINATED CLOTHING BEFORE REUSE.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:NON-COMBUSTIBLE. USE EXTINGUISHING MEDIA
    APPROPRIATE TO SURROUNDING FIRE CONDITIONS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:EMITS TOXIC FUMES UNDER FIRE CONDITIONS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WEAR NIOSH/MSHA APPROVED SCBA, RUBBER BOOTS
    AND HEAVY RUBBER GLOVES. SWEEP UP, PLACE IN A BAG AND HOLD FOR
    WASTE DISPOSAL. AVOID RAISING DUST. VENTILATE AREA AND WASH SPILL
    SITE AFTER MATERIAL PICK UP  IS COMPLETE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT BREATHE DUST. DO NOT GET IN
    EYES, ON SKIN, ON CLOTHING. IRRITANT. KEEP TIGHTLY CLOSED.
    HYGROSCOPIC. STORE IN A COOL, DRY PLACE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:MECHANICAL EXHAUST REQUIRED.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH CONTAMINATED CLOTHING BEFORE REUSE. WASH
    THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
WASTE DISP METH: GENERATE HEAT & FUMES, WHICH CAN BE CONTROLLED BY RATE
    OF ADDITION. OBSERVE ALL FED, STATE, & LOC LAWS.

==================  Physical/Chemical Properties  ==================

Spec Gravity:1.569
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS. PROTECT FROM MOISTURE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:TOXIC FUMES OF HYDROGEN CHLORIDE GAS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:FOR SML QTYS: CAUTIOUSLY ADD TO LGE STIRRED
    EXCESS OF WATER. ADJUST PH TO NEUTRAL, SEPARATE ANY INSOLUBLE
    SOLIDS/LIQS & PACKAGE THEM FOR HAZ WASTE DISP. FLUSH AQUEOUS SOLN
    DOWN DRAIN W/PLENTY OF WATER . HYDROLYSIS & NEUTRALIZATION RXNS MAY
    (SUP DAT)

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.